On this page
The MCP configuration file depends on the client and may also depend on its version or operating system. Putting an entry in a plausible-looking file is not enough: the editor must load it, and the Hemory connection must be configured as that client expects.
Use the checklist below to confirm the location for Cursor or VS Code before editing. It avoids relying on paths copied from another editor or an outdated example.
TL;DR
- Check the official MCP setup documentation for the exact client, version, and operating system you use.
- Compare it with Hemory’s own setup guidance. The supplied Hemory Features page describes a standard MCP server, but does not give Cursor or VS Code configuration paths or setup steps.
- Confirm the file location, entry requirements, and how to tell that the client loaded the connection before making changes. Do not assume a restart is required.
Verify the location before editing
1. Identify your client and environment
Confirm whether you are setting up Cursor or Visual Studio Code, and note the version and operating system. Client documentation can change, and instructions for one editor—or one version—may not apply to another.
2. Find the client’s official MCP instructions
Use the editor’s current official documentation or setup interface to locate its instructions for adding an MCP server. Confirm the exact configuration file or settings location for your client and environment. If the documentation offers more than one setup method, follow the one that matches your installation and intended scope.
Do not substitute a path from a forum post, an older guide, or another client’s configuration example. Similar-looking configuration files do not establish that an editor reads them.
3. Check Hemory’s setup guidance separately
Confirm that Hemory’s current instructions cover your chosen client and specify the server details the client needs. Hemory’s Features page describes a standard MCP server and names Claude Code, Codex, and Hermes as examples; it does not provide Cursor or VS Code file locations or setup instructions. That page alone does not verify a connection procedure for either editor.
If you cannot find current official instructions for your client, do not copy a Hemory entry from an unrelated example and treat it as confirmed. Find the missing setup details before editing.
4. Confirm the exact file and loading behavior
Before changing a file, make sure the client’s documentation answers these questions:
| Check | What to confirm |
|---|---|
| Location | The exact file or settings area for your client, version, and operating system |
| Entry | The required fields and format, using Hemory’s current setup instructions |
| Scope | Whether the setting applies to the current project, user, or another documented scope |
| Loading | How the client recognizes or reports a valid MCP connection, and whether it requires a reload or other action |
Do not assume that saving a file is enough, or that restarting is always necessary. Follow the loading instructions for the client and setup method you are using.
5. Test the connection without guessing
After following the confirmed instructions, use the client’s documented way to check whether the MCP server is available. If it does not appear or connect, compare the file location and entry with both official setup guides, then use the client’s documented troubleshooting steps. A failed connection does not by itself prove that the file path is wrong; other configuration details may also need attention.
Hemory provides MCP access to captured Memory; the connected client handles its own connection and any subsequent reasoning or drafting. Use only information and actions that the configured client and Hemory connection actually support.
What to do when the instructions do not match
If Hemory’s guidance and the editor’s instructions appear inconsistent, pause before editing. Confirm that both describe the same client, version, and setup method. Prefer current official instructions over a copied example, and seek clarification from the relevant support channel if the required path or entry remains unclear.
The supplied Hemory product page does not settle the Cursor and VS Code file locations, required entry contents, or reload behavior. Those details must be checked in current official setup documentation; this guide does not provide unverified paths or configuration snippets.
FAQ
Is there one MCP configuration file shared by Cursor and VS Code?
Do not assume so. Check each editor’s current documentation separately; a configuration location or loading process for one client does not establish the other’s.
Does Hemory’s Features page show where to put its MCP entry?
No. It describes Hemory’s MCP server and lists some example clients, but does not give Cursor or VS Code paths or setup instructions.
Should I restart the editor after changing the configuration?
Follow the instructions for your client and setup method. The available information here does not confirm that either editor always requires a restart or reload.
Can I use a configuration snippet from another MCP client?
Not as confirmation. Use Hemory’s instructions for the chosen client and check the client’s own requirements before adapting any example.
Before editing, make sure the client documentation and Hemory setup guidance agree on the location and connection requirements. That small check is more reliable than trying likely filenames or carrying settings over from a different editor.